ONICON INCORPORATED U.S.A

FLOW & ENERGY MEASUREMENT SYSTEMS

To ensure the highest return on investment, a comprehensive metering program is essential for managing today’s complex central energy plants:

Accurate flow and energy measurement provides:

  • Improved chiller plant control
  • Real time commissioning and balancing data
  • Continuous monitoring of chiller performance (KW/Ton)

Onicon is having following type flow meters.

  • Insertion turbine type (Dual or single turbine)
  • Insertion magnetic type
  • Inline magnetic meter
  • Clamp on ultrasonic flow meters
  • Inline vortex mass flow meter for saturated steam
  • Thermal mass flow meters for natural gas

ONICON’s flow meters have become the recognized standard for accurate, reliable flow measurement at a reasonable cost.

Onicon is having following type energy measurement meters.

  • Inline electromagnetic type BTU 30 meters (for upto 38gpm)
  • BTU 10 meters for higher flow rates
  • Clamp on ultrasonic btu meters

Onicon’s BTU meters utilize a calibrated system approach to provide highly accurate flow, temperature and energy data. Further more with a serial network communication option, this system can actually be less expensive than traditional energy calculation methods.

BTU meters configured with serial network communications offer simplified wiring and greatly reduced installation cost compared to traditional analog/pulse type outputs. The data provided (with a single 2-3 wire LAN connection) includes: energy total, energy rate, flow total, flow rate, supply temperature, and return temperature, delta temperature.

The flow,temperature and energy information that is provided useful for:

  • Overall system performance verification during commissioning
  • Establishing baseline standards for system performance
  • Determining current system capacity vs future needs for growth planning
  • Monitoring the success of new and ongoing conservation efforts
  • Cost allocation for individual buildings and departments
  • Control applications such as chiller and boiler staging
  • Monitoring individual chiller and boiler efficiency
  • Hydronic system troubleshooting and optimization.

WEBSITE : www.onicon.com (DISTRIBUTOR FOR UNITED ARAB EMIRATES,QATAR,SAUDI ARABIA,KUWAIT,BAHRAIN,OMAN)

Almi International

AIR MONITOR AIRFLOW MEASUREMENT SOLUTIONS(U.S.A)

A. BUILDING AIRFLOW MEASUREMENT & CONTROL

The distribution of conditioned air is still the primary means of heating and cooling most commercial buildings today. Proper airflow control within a building is not only important for the health and comfort of the building occupant’s, it is also important for the health and long term performance (longevity) of the building. Accurate airflow measurement allows the HVAC system to work effectively, as designed, and efficiently, as required to meet the ever increasing energy conservation goals. A few of the typical strategies implemented for this application include:

1. Ducted Airflow Measurement & Control

Mechanical ductwork is the most common means for distributing the conditioned air throughout most commercial buildings. The duct system provides the best opportunities for accurate airflow measurement due to its controlled dimensions, and the typical obstructions found within a duct system are generally well defined.

The products below are commonly used for this application:

  • ELECTRA-flo Thermal Airflow Measurement Probe Array
  • ELECTRA-flo/CM Thermal Airflow Measurement Station
  • VOLU-probe Pitot Airflow Measurement Traverse Probe
  • VOLU-probe/VS Pitot Airflow Measurement Traverse Station

2. Fan Discharge Measurement

Measuring airflow at the fan inlet presents challenges from a measurement technology stand point. Achieving accurate flow measurement at the fan inlet, without affecting fan performance, is an important consideration when selecting the correct meter. The large variation in airflow velocity, as well as the multiple fan configurations that exist within an AHU, must be taken into consideration. Measuring airflow at the fan inlet can be advantageous from an accessibility stand point as well as monitoring the performance of fan walls at the source.

The products below are commonly used for this application:

  • ELECTRA-flo Thermal Airflow Measurement Probe Array
  • ELECTRA-flo Thermal Airflow Measurement Probe Array
  • ELECTRA-flo/CM Thermal Airflow Measurement Station
  • VOLU-probe Pitot Airflow Measurement Traverse Probe
  • VOLU-probe/VS Pitot Airflow Measurement Traverse Station
  • FAN E – Pitot Airflow measurement Traverse station with Honeycomb air straightner

3. Fan Inlet Measurement

stand point. Achieving accurate flow measurement at the fan inlet, without affecting fan performance, is an important consideration when selecting the correct meter. The large variation in airflow velocity as well as the multiple fan configurations that exist within an AHU must be taken into consideration. Measuring airflow at the fan inlet can be advantageous from an accessibility stand point as well as the advantage of monitoring the performance of fan walls at the source.

The products below are commonly used for this application:

  • ELECTRA-flo/FI Thermal Fan Inlet Airflow Measurement Probe
  • VOLU-probe/FI Pitot Fan Inlet Airflow Measurement Probe
  • VELTRON DPT2500-plus Transmitter
  • VELTRON II Transmitter

4. Outdoor airflow Monitoring

Controlling the amount of outside air entering a building is required to maintain pressurization, meet energy efficiency goals, confirm compliance with local building codes and maintain the health of the building and its’ occupants. The accurate measurement of outside airflow is required for the proper operation of today’s high performance buildings. Outside air can pose a challenge regarding the metering technology to choose due to low airflow velocities, high moisture content in certain climates and the presence of airborne contaminants at the point of measure. The products below are commonly used for this application.

The products below are commonly used for this application:

  • VOLU-Flo/OAM outside air monitor

 

B. BUILDING/SPACE PRESSURIZATION

Proper pressurization of buildings and indoor spaces is a crucial component required for the management of indoor air quality, maximizing energy efficiency and maintaining occupant health and comfort. Lack of control in regards to pressurization can lead to a host of problems including the infiltration of moisture, cold winter or hot summer drafts and doors that are difficult to open or slam shut. A few of the typical strategies implemented for this application include:

1. Fan Tracking For Building Pressurization

Proper fan tracking requires the accurate measurement of the entire airflow system including supply and return air, outside air and relief air, all of which are required to maintain proper air balance and thus control the building pressurization. Airflow measurement, which can be achieved through fan tracking, is a much more effective and accurate means of maintaining building pressurization when compared to static pressure measurements made throughout an entire building.

The products below are commonly used for this application:

  • ELECTRA-flo Thermal Airflow Measurement Probe Array
  • ELECTRA-flo/CM Thermal Airflow Measurement Station
  • VOLU-probe Pitot Airflow Measurement Traverse Probe
  • VOLU-probe/VS Pitot Airflow Measurement Traverse Station

2.Outside Reference Pressure Measurement

In order to properly pressurize a room or other interior space, pressures must be measured relative to a reference pressure. In most applications, this reference is the outside air pressure. If the reference pressure is an adjacent room or hallway, then the reference pressure to that measurement should be outside air.

The products below are commonly used for this application:

  • S.O.A.P – Static Outside Air Probe

3.Room or Space Pressurization

Proper pressurization of buildings and indoor spaces is a crucial component required for the management of indoor air quality, maximizing energy efficiency and maintaining occupant health and comfort. Lack of control in regards to pressurization can lead to a host of problems including the infiltration of moisture, cold winter or hot summer drafts and doors that are difficult to open or slam shut.

The products below are commonly used for this application:

  • S.A.P. – Static Air Pressure Sensors
  • STAT-probe – Static Pressure Traverse Probe
  • SENTRY Room Pressurization Monitor
  • VELTRON DPT2500-plus Transmitter

 

C. INDOOR AIR QUALITY

  • Ducted Airflow Measurement
  • Fan Inlet Measurement
  • Laboratory & Hood Exhaust
  • Outdoor Airflow Monitoring
  • Room or Space Pressurization

BURPROVENT GERMANY

CAR PARK & TUNNEL VENTILATION SYSTEM

BURPROVENT is a young & dynamic company and because of the unique experience, built up throughout the past years by executing over 1000 car parks & tunnels all over the world.BURPROVENT has the capacity to create custom made , highly competitive and innovative(compared to ducted car park ventilation system)solutions for all Car parking & tunnel ventilation system.

People are used to traditional ducted system in the car parks. The latest technology showed lot of disadvantages of this system.

Disadvantages of traditional ducted systems are:

  • Availability of space for air Supply / Exhaust points is limited.
  • The air movement and air mixing in the car park are not enough to avoid pollution.
  • Dead non ventilated corners
  • Limited space for duct work.
  • No controlled smoke exhaust
  • High Energy Consumption
  • Loss of parking spaces

To overcome all these problems, Mr.Ralf Burkhardt a tunnel ventilation specialist, the founder of Burprovent has developed car parking ventilation system using Impulse type Jet fans and is heading the design team of Burprovent. He has adopted tunnel ventilation methods to car park ventilation systems & proved the system .This Car parking system is an intelligent system where the operation of the Jet fans, main extract & supply fans are controlled by CO & Fire detection systems.

The following advantages of the Burprovent germany make Impulse type jet fans.

  • Reduction in the parking height
  • Less units of fans required to do the same work of Impulse fans.
  • Reduction in Electrical components & cables.
  • dReduction in the energy consumption.
  • Smaller Back up power supply
  • Reduction in the Installation & Maintenance cost

Burprovent Germany provides complete design of Car parking ventilation system which is supported by CFD analysis.

WEBSITE : www.burprovent.com (DISTRIBUTOR FOR UNITED ARAB EMIRATES,QATAR,SAUDI ARABIA,KUWAIT,BAHRAIN,OMAN)

MARS USA

AIR CURTAINS

Mars Air Systems has been manufacturing high quality air curtains for over 50 years. MARS air curtains protect building environments from energy loss and windborne dust, dirt and fumes, along with flying insects. The air barrier created by the light stream of air over a doorway helps to improve inside sanitation and reduce operational energy costs.

Mars Air Curtains qualify for LEED point credits when utilized with in a building management system and help to support Green Build initiatives. Mars is a global company with factory trained manufacturers representatives and dealers/distributors located across the US and internationally.

WEBSITE : www.marsair.com (DISTRIBUTOR FOR UNITED ARAB EMIRATES,OMAN)

Quatrosense Environmental Ltd. (QEL)-CANADA

Toxic and combustible gas detection equipment

Helping to protect building occupants and property, QEL is a leader in manufacturing toxic and combustible gas detection equipment. With a diverse product offering, we are able to satisfy both commercial and industrial toxic and combustible gas detection applications.

Commercial applications include carbon monoxide and nitrogen dioxide monitoring in parking garages, carbon dioxide monitoring in schools and auditoriums, to Freon detection in chiller rooms.

Industrial applications include ammonia monitoring in the agriculture industry, carbon dioxide and ammonia monitoring in the food and beverage industry, to monitoring toxic and combustible gases for the United Space Alliance, aerospace industry.

1. Toxic gas transmitters/ sensors(various gases)

2. Carbon dioxide transmitter/ sensors

3. Toxic or combustible gas transmitter/sensors (various gases)

4. Refrigerant gas transmitters/ sensors

5. Oxygen transmitters/ sensors

6. Non intrusive toxic or combustible gas transmitters/ sensors

WEBSITE : www.qelsafety.com

PURIFIED AIR UK- The Commercial Kitchen Filtration Experts

Purified Air the specialist in the filtration and control of commercial kitchen exhaust systems

Since 1984, Purified Air has been striving to find the best and most cost effective way to filter and control the oil, smoke, grease and odour produced by commercial kitchens.

Purified Air specializes in the filtration and control of commercial kitchen exhaust systems based on the understanding of the two distinct phases:

1. The particulate phase; oil, grease and smoke (carbon) particles.

2. The gaseous phase or odour.

Oil, Grease & Smoke Filtration: Electrostatic Precipitators or ESP’s effectively filter the particulate phase specifically for commercial kitchen application. These units utilize an ionization process to filter particles down to submicron level, with an optimum efficiency of up to 98%.

The ESP units fit in-line with the kitchen ducting and can be configured modularly to cope with all extract volume requirements.

• ESP 1500E

• ESP 3000E

• ESP 4500E

• ESP 6000E

Odour Control: Ultra Violet Units or Ozone Generators as well as Odour Neutralizer - ON100, efficiently control the gaseous phase.

UV-C: UV-C (short-wavelength ultraviolet radiation) technology is based on the synergy which occurs when ozone and ultra violet light are combined. Purified Air have the best combination of lamps at different wave lengths, which when combined with the photo catalytic liner provides the most effective odour control.

• UV-C 1500

• UV-C 3000

• UV-C 4500

UV- O: Unlike other UV-C systems, UV-O units are located outside of the kitchen extract duct and are connected via a spigot and spiral ducting The UV-O range uses UV-C technology to produce ozone and hydroxyl free radicals to oxidise cooking odours through a process of ozonolysis.

• UV-O 500

• UV-O 1000

ON 100: The vapor from a specially blended neutralizing agent, ELIMINODOR , is mixed with ambient air drawn into the ON100 and ionized, this ionized vapor then passes along a nonconductive tube to be discharged into the centre of the duct via a venturi spigot, the metal ducting is earthed through the same high tension circuit which makes the contaminant at an opposite potential to the negatively charged ELIMINODOR vapor. and causes the negative and positive particles to combine, so treating the malodour by chemical reaction.

Purified Air also supplies Passive Filtration, including:

Activated Carbon- Sitesafe carbon filters use panels of activated carbon to remove the malodorous gases within the commercial kitchen extract duct through the process of chemical adsorption.

HEPA - Called a High-Efficiency Particulate Air or HEPA filter, the filter removes from the air that passes through it, 99.97% of particles down to a sub-micron level. Main use of HEPA filtration is the removal of smoke particles.

Bag Filters- Bag filters are manufactured using a galvanised steel header to retain the pocket sets. The pockets are produced from synthetic micro-fibres specifically designed for use in air filtration.

Pleated Panel Filters.- Pleated panel filters are core of pleated fibrous media thermally bonded onto a galvanised steel support mesh for maximum rigidity which is then fully bonded into a moisture resistant rigid white lined card frame. These filters are used as stand-alone pre filters or as a pre filter to bag filters filtering oil and grease particles.

WEBSITE : www.purifiedair.com

our clients :

Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International Almi International